Mechanical sign-off
Send the envelope, mounting thread and gender, seating face, connector clearance and cable exit.
METRIX / IMI / WILCOXON / HANSFORD / IFM
Vibration transmitter cross-references are a starting point for engineering review. A matching range or connector does not establish interchangeable operation.
Send an original model & drawing ↗
Reference data identify the original equipment. Each VTX request still needs its controlled drawing, detector, pinout and environmental review.
| Original model / source | Detector & full scale | Electrical / mounting interface | VTX review entry |
|---|---|---|---|
| Metrix ST5484E-121 / -122 / -123Manufacturer source ↗ | RMS-derived Peak 1.0 / 0.5 / 2.0 in/s respectively | Exact mounting / connection suffix required Rev BG identifies derived peak. Confirm PLC detector and each mechanical suffix. | VTX-420-LF configuration review → |
| Metrix ST5484E-151 / -152 / -153Manufacturer source ↗ | True RMS 1.0 / 0.5 / 2.0 in/s respectively | Thread pitch, gender and connection depend on suffix M8 × 1.0 and M8 × 1.25 are different options. Match the full ordering code. | VTX-420-LF configuration review → |
| Metrix SW5484EManufacturer source ↗ | Relay / current functions by original configuration Setpoint / detector review | Supply, relay contacts, mounting and reset Listed as discontinued by Metrix, which also lists its own successor. Review electronic supply and relay behavior. | VTX-SW configuration review → |
| Metrix AM3030Manufacturer source ↗ | Controller input / alarm configuration Input scaling to confirm | Panel / cabinet, relay and input power Review input excitation, engineering scale, relay rating and fail-state. | VTX-DIN configuration review → |
| Wilcoxon PC420VR / PC420VP / -DAManufacturer source ↗ | VR = RMS, VP = Peak -05 / -10 / -20 = 0.5 / 1.0 / 2.0 in/s | MIL / cable / mounting per exact suffix -DA adds dynamic acceleration output. Specify VTX-420D review if that second signal is required. | VTX-420 configuration review → |
| Wilcoxon PC420AR / PC420APManufacturer source ↗ | AR = RMS, AP = Peak acceleration Acceleration g, not velocity in/s | Original drawing and calibration required Use acceleration output in the RFQ. A velocity profile does not define the required g range. | VTX-420 configuration review → |
| Hansford HS-420 M12 TS029.8 / HS-421Manufacturer source ↗ | RMS / option by exact model 0–10 / 20 / 25 / 50 mm/s by configuration | HS-420 TS029.8: Pin 2 +, Pin 4 return The cited M12 revision specifies 15–30V and 10–1000Hz. Obtain the HS-421 document separately for dual output. | VTX-420 configuration review → |
| IFM VTV122Manufacturer source ↗ | RMS 0–25 mm/s, 10–1000Hz | Pin 1 L+, Pin 2 current output Single-axis analog current output. IO-Link models use a different interface. | VTX-420 configuration review → |
| Banner QM30VT2 / -SSManufacturer source ↗ | Two-axis vibration features + temperature Feature/register review | RS485 Modbus RTU The standard referenced model is aluminum IP67. Get the exact stainless model data and map before replacing. | VTX-MOD configuration review → |
| SICK MPB10Manufacturer source ↗ | Three-axis features, shock and temperature Process-data / service-data review | IO-Link Request IODD and feature mapping. A Modbus sensor needs a different controller connection. | VTX-MOD-IOL configuration review → |
| IMI 640B / 641B / 655A / 656AManufacturer source ↗ | Confirm detector from full model document Original full scale and passband required | Connector and pinout to confirm Supply the current manufacturer datasheet and complete suffix for a numerical comparison. | VTX-420 configuration review → |
| Sensonics PZDC / Emerson AMS CSI | Identify exact original architecture Original datasheet required | Analog, wired digital or wireless to identify Send the complete original model, host system and document revision for manual configuration review. | Manual configuration review → |
Third-party names identify the original equipment. Complete suffixes, drawing revisions, certifications and controller configuration determine the review scope.
Send the envelope, mounting thread and gender, seating face, connector clearance and cable exit.
Send supply, current burden, AI type, connector pin numbers, isolation and fault behavior.
Send units, RMS / Peak, frequency band, axis, response time and required calibration.
MATING CONNECTOR / MOUNT / CABLE
Confirm the drawing for both ends of the connection. A familiar plug or thread does not establish wiring or mechanical compatibility.

Confirm coding, pin assignment and cable-exit clearance.

Check mating gender, contact assignment and locking clearance.

Match pitch, gender, usable depth and seating faces.
PLANT-WIDE QUOTE / CAD REVIEW
Include the machine, original model and control input. Attach a nameplate or asset list and request the drawings and records needed for purchasing.
[email protected]Prefilled email carries your current selections. Add the listed files in your email client.
Ask for sensor-only and installation-kit line items at your exact quantity. Studs, calibration scope, warranty and delivery will appear in the written quote.
Download the asset-list CSVVibration Transmitters | Plant-wide vibration monitoring RFQ Name: Request profile: Configuration review Request purpose: Configuration advice / project review Band: Confirm band and response tolerance Exact quantity: To confirm Wireless kit: Not selected Documents requested: None Company / plant: Reply email: Series entry: Unspecified Machine: Electric motors, pumps & fans Output: 2-wire 4–20mA velocity [RMS / Peak by configuration] Range: Confirm range / digital features in brief Connector / mounting: Other / confirm with drawing Mounting thread: Confirm thread, gender and depth in brief Connection exit: Confirm from model / clearance drawing Original pinout to review: To confirm from drawing Detector: Confirm per configuration Original model: Not specified Quantity band: 1-5 Accessories: None Source: /metrix-imi-wilcoxon-hansford-ifm-replacement/ Operating speed / RPM: To confirm Ambient / bearing temperature: To confirm PLC / receiving system: To confirm Destination country / site: To confirm Interface and operating requirements: To confirm during configuration review Project brief: Configuration, certification, compatibility, price and delivery subject to written review.