Vibration Transmitters
Menu

PRODUCT FAMILIES / TRANSMITTERS BY TYPE

Industrial vibration sensors.
Five paths to your plant data.

Choose analog, digital, wireless, harsh-duty or relay monitoring. Start with the machine and the control interface, then confirm the configuration.

Compare signal interfaces ↓
Wireless monitoring gateway enclosure with two compact vibration sensor nodes
Choose the sensor, control interface and installation components as one monitoring system.

Match the monitoring task to your control interface.

Compare request profiles, then open the family guide or carry a profile into your RFQ. Confirm ranges, mounting and released ratings during the configuration review.

12 request profiles
VTX configuration profiles by measurement and receiving interface
Request profileMeasurementInterface / check before orderingPrepare the request
VTX-420
Standard loop-powered velocity
Velocity RMS or PeakM12 / MIL / integral cable

Confirm detector, full scale, supply/load and pinout.

Configure RFQ →Request 2–5 evaluation units →
VTX-420-LF
Low-speed machine velocity
Low-frequency velocityTop or side exit

Verify mounted low-frequency response and noise at actual RPM.

Configure RFQ →Request 2–5 evaluation units →
VTX-420T
Velocity plus surface temperature
Velocity + temperatureSeparate temperature conductors / loop

Specify PT100 or current output and the full wiring topology.

Configure RFQ →Request 2–5 evaluation units →
VTX-420D
Velocity plus buffered dynamic output
4–20mA + dynamic accelerationSeparate dynamic acquisition connection

Confirm dynamic sensitivity, bias, power and analyzer loading.

Configure RFQ →Request 2–5 evaluation units →
VTX-MOD
Triaxial Modbus vibration + temperature
X/Y/Z features + °CRS485 Modbus RTU

Request register map, data type, units, scale and word order.

Configure RFQ →Request 2–5 evaluation units →
VTX-MOD-IOL
IO-Link vibration + temperature
Axis count and process data to confirmOne sensor per IO-Link master port

Request IODD, master port requirements and process-data layout.

Configure RFQ →Request 2–5 evaluation units →
VTX-SCR
Screen stroke / heavy-duty motion
0–10 / 20 mm peak-to-peak requested4–20mA + protected cable

Specify stroke, frequency, shock and cable restraint drawing.

Configure RFQ →Request 2–5 evaluation units →
VTX-420-EX
Hazardous-area configuration review
Velocity / acceleration by configuration1/2 NPT / M20 conduit request

Certification availability, full marking and loop parameters require review.

Configure RFQ →Request 2–5 evaluation units →
VTX-WLS
Wireless vibration + temperature node
Triaxial features + °C requestedLoRaWAN or separate WirelessHART option

Confirm radio region, duty cycle, battery, gateway and local data path.

Configure RFQ →Request 2–5 evaluation units →
VTX-GW
Local industrial gateway kit
Node aggregation / plant integrationMQTT / Modbus TCP, OPC UA by review

Specify protocol, local server, licensing, offline operation and support scope.

Configure RFQ →
VTX-SW
Electronic vibration relay monitor
Alarm / trip setpoint reviewRelay + optional current output

Confirm external supply, startup delay, reset and power-loss state.

Configure RFQ →Request 2–5 evaluation units →
VTX-DIN
DIN-rail display + alarm monitor
4–20mA process input / local display35 mm rail / panel format by option

Confirm whether the input powers the loop, relay rating and reset logic.

Configure RFQ →Request 2–5 evaluation units →

For hazardous areas, include the zone, gas/dust group and required certificate scheme. Certification availability is reviewed for the exact configuration. Evaluation-unit pricing, availability and acceptance criteria are confirmed in writing.

Review the wiring, mounting and data path for each family.

PLANT-WIDE QUOTE / CAD REVIEW

Specify the signal.
Send the complete brief.

Include the machine, original model and control input. Attach a nameplate or asset list and request the drawings and records needed for purchasing.

Prefilled email carries your current selections. Add the listed files in your email client.

Plan a pilot and a full-plant rollout.

Ask for sensor-only and installation-kit line items at your exact quantity. Studs, calibration scope, warranty and delivery will appear in the written quote.

Download the asset-list CSV
Preview the current email brief
Vibration Transmitters | Plant-wide vibration monitoring RFQ
Name: 
Request profile: Configuration review
Request purpose: Configuration advice / project review
Band: Confirm band and response tolerance
Exact quantity: To confirm
Wireless kit: Not selected
Documents requested: None
Company / plant: 
Reply email: 
Series entry: Unspecified
Machine: Electric motors, pumps & fans
Output: 2-wire 4–20mA velocity [RMS / Peak by configuration]
Range: Confirm range / digital features in brief
Connector / mounting: Other / confirm with drawing
Mounting thread: Confirm thread, gender and depth in brief
Connection exit: Confirm from model / clearance drawing
Original pinout to review: To confirm from drawing
Detector: Confirm per configuration
Original model: Not specified
Quantity band: 1-5
Accessories: None
Source: /products/
Operating speed / RPM: To confirm
Ambient / bearing temperature: To confirm
PLC / receiving system: To confirm
Destination country / site: To confirm
Interface and operating requirements:
To confirm during configuration review
Project brief:

Configuration, certification, compatibility, price and delivery subject to written review.
Operating conditions & interface details (optional)
Installation kit · quote each selected option
Documents for the selected configuration

Up to 3 files. PDF, PNG, JPEG, UTF-8 CSV/TXT or XLSX. 2 MB each, 5 MB total. Files are delivered with your inquiry email.